Design of grounding scheme for mobile substation

Rong Mao * 1 , Tao Du 2 , Yingtao Shu 3 , Mingyan Shi 4 , Liang Dai 5
1 Xi’an XD High Voltage Apparatus Co., Ltd.
2
3
4
5

* Author to whom correspondence should be addressed.

Advances in Engineering Innovation, Vol. 9, 1-5
Published 10 July 2024. © 10 July 2024 The Author(s). Published by EWA Publishing
This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Citation Rong Mao, Tao Du, Yingtao Shu, Mingyan Shi, Liang Dai. Design of grounding scheme for mobile substation. AEI (2024) Vol. 9: 1-5. DOI: 10.54254/2977-3903/9/2024081.

Abstract

The rational design of a grounding grid is a crucial prerequisite for ensuring the safe and reliable operation of mobile substations. This paper discusses the design of the grounding grid for mobile substations from the perspective of standardized design, aiming to minimize on-site construction and enable rapid deployment. It introduces a type of grounding ring network design that can ensure the entire equipment forms a reliable equipotential grounding, thereby enhancing the operational reliability of mobile substations.

Keywords

mobile substation, grounding design, grounding ring network

References

1. Guo, R., & Wu, J. (2018). Seismic design scheme for mobile substations. Electronic Technology and Software Engineering.

2. Bao, H. Q. (2013). Large-scale mobile substations. Electric Applications.

3. Yang, S. (2015). Discussion on the grounding grid of mobile substations. Guizhou Electric Power Technology.

4. National Standard of the People’s Republic of China. (2006). GB 3906—2006: AC metal-enclosed switchgear and control equipment rated from 3.6kV to 40.5kV.

5. National Standard of the People’s Republic of China. (2016). GB 50169—2016: Installation engineering for grounding devices - Construction and acceptance specification for grounding devices.

6. Power Industry Standard of the People’s Republic of China. (1997). DL/T 621—1997: Grounding of AC electrical installations.

Data Availability

The datasets used and/or analyzed during the current study will be available from the authors upon reasonable request.

This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License. Authors who publish this journal agree to the following terms:

1. Authors retain copyright and grant the journal right of first publication with the work simultaneously licensed under a Creative Commons Attribution License that allows others to share the work with an acknowledgment of the work's authorship and initial publication in this journal.

2. Authors are able to enter into separate, additional contractual arrangements for the non-exclusive distribution of the journal's published version of the work (e.g., post it to an institutional repository or publish it in a book), with an acknowledgment of its initial publication in this journal.

3. Authors are permitted and encouraged to post their work online (e.g., in institutional repositories or on their website) prior to and during the submission process, as it can lead to productive exchanges, as well as earlier and greater citation of published work (See Open Access Instruction).

Volume Title
ISBN (Print)
ISBN (Online)
Published Date
10 July 2024
Series
Advances in Engineering Innovation
ISSN (Print)
2977-3903
ISSN (Online)
2977-3911
DOI
10.54254/2977-3903/9/2024081
Copyright
10 July 2024
Open Access
This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited

Copyright © 2023 EWA Publishing. Unless Otherwise Stated